Note: The latest update can be skipped if it doesn't apply to your installation or usage.
Please see here
Bug fixes and Improvements v8.0.6584 - 15th February 2022
Note: This release is for Windows 10 and 11 only.
- Macrium Image Guardian
On some systems, MIG could generate a Stack Trace event for a non-blocked remote file operation. This has been resolved.
For more information on this functionality please see here
- File and Folder
File and Folder restores could fail if the restored path was greater than 256 characters. This has been resolved.
- Clone Power Saving Options
When taking a clone, any change to the after Clone shutdown option would be incorrectly overruled by the Power Saving options in the clone definition. This has been resolved.
|
Bug fixes and Improvements v8.0.6562 - 8th February 2022
- Technicians License
This patch only applies to Technicians Portable Rescue Media, and corrects a build problem when creating portable media using v8.0.6560.
|
Bug fixes and Improvements v8.0.6560 - 7th February 2022
- Localization
- We've added Korean, Italian and Turkish localizations. German, French and Japanese translations have been improved and now have much better coverage of the UI text and more accurate translations.
We would like to thank our localization contributors for their outstanding help with the Macrium Reflect localization project. For credits, please take the 'Help' > 'About' menu option and click 'Localization Contributors'
- Rescue Media
- We've added font and language pack support for PE 10/11. The language pack files for Japanese, Korean, Russian and Ukrainian will be added automatically during the build process. Fonts for Japanese and Korean will also be included.
- The Rescue Media Builder now has an option to copy IP and DNS settings from the host PC into the rescue media.
- For each device on the Advanced Options Drivers tab, there is now an option to not copy drivers from the host machine, even if there are no corresponding drivers already available in the WinPE/WinRE wim.
- On the Advanced Options Drivers tab, selecting the Use Host Driver drop-down option would not always change the driver status. This has been resolved.
- When creating USB-based Windows PE 3 rescue media, the Multi-boot (MBR/UEFI) option could sometimes be selected, even though PE 3 does not support multi-boot. This has been resolved.
- A recent Windows update on some Windows 10 or 11 systems caused WinRE based Rescue Media ISO files/Optical media to fail to UEFI boot if created after the update. This has been resolved. Please re-create ISO files/Optical rescue media if this affects you.
- On-board AMD RAID devices were not being correctly detected/handled when creating rescue media. This has been resolved.
- Imaging
- We've added support for Hardware/Self Encrypting Drives (SED). Volumes on a SED will be treated the same as software BitLocker encrypted volumes, with the same backup and restore outcomes.
- Change Block Tracker – Minor performance improvements.
- Volume Access Driver – Minor performance improvements.
- File and Folder
- The File and Folder backup wizard would select both Folder and CD radio options at the same time. This has been resolved.
- The Add Folder dialog was not showing volume mount points. This has been resolved.
- The search controls in the File and Folder backup view could disappear when changing source folders. This has been resolved.
- Image Guardian
- Server Plus
- The first page of the Exchange Mailbox Restore wizard will now show the backup definition name for each Exchange backup.
- In rare situations, a scheduled Exchange backups running as SYSTEM could falsely report "The specified module could not be found". This has been resolved.
- General
- When shutting down after a backup, the notification pop-up now has the option to postpone the shutdown. This new option is also available for rebooting, hibernating or suspending after a backup.
- We've added a new toolbar button in the Existing Backups View to create and amend backup/image comments.
- We've added a new toolbar button in the Existing Backups View to automatically size all columns to fit the data.
- The Log View now retains all custom column widths.
- When viewing a specific backup, the Log View would also open the most recent backup log. This has been resolved.
- Backup logs from v7 could occasionally not be found when viewing specific backup log. This has been resolved.
- Verification, Browse and Restore functions were unavailable for images/backups spanning multiple locations, such as those created with multiple optical media discs. This has been resolved.
- A rare FAT32 detection issue was reported with a mis configured FAT32 volumes. This has been resolved.
- A program exception could occur when performing the Analyze File System operation from the Drive Partition view. This has been resolved.
- We've resolved a random crash when sending backup failure emails.
- Macrium Reflect could hang for many seconds at startup if a Windows network share was mapped to a drive letter in the context of an elevated Admin user. This has been resolved.
.
- Scheduler
- Postponed scheduled backups will now minimize to the system tray, with new options to postpone the backup further or to run immediately.
- If a scheduled backup is configured to send an email on backup failure, then the Macrium Task Scheduler will now attempt to send the email itself if Reflect failed to launch.
- Various
Various minor fixes and changes to improve Macrium Reflect.
|
Bug fixes and Improvements v8.0.6392 - 18th November 2021
- Rescue Media
Some customers have reported incorrect drive letter assignments in Windows PE. This has been resolved.
If this issue affects you then please create fresh rescue media after updating.
- Server Plus
Improved performance of the Exchange Mailbox Restore wizard when selecting folders or mailboxes.
- Changed Block Tracker
We've added extra detection for nonconforming 3rd party file system kernel filter drivers to prevent system exceptions.
- Various
Various minor fixes and changes to improve Macrium Reflect.
|
Bug fixes and Improvements v8.0.6353 - 6th November 2021
- Encrypted Backups
After upgrading to v8.0.6350, scheduled encrypted backups failed with 'File is encrypted and supplied password is incorrect'. This has been resolved.
|
Bug fixes and Improvements v8.0.6350 - 6th November 2021
- Macrium Reflect Free
- Localization
- We've added French, Russian and Ukrainian translations to Macrium Reflect, and improved the coverage of translated strings.
- Windows 11
- Support has been added in RMBuilder for the Windows 11 PE Rescue Environment.
- The rescue media now correctly automatically assigns drive letter 'C' to the Windows 11 system drive.
- The rescue media now correctly identifies and labels Windows 11 for 'Fix Boot Problems' and 'ReDeploy'
- We've fixed a problem that could cause a Windows 11 disk clone to hang at the end of the clone process.
If this affects you then please create fresh rescue media after updating.
- Rescue Media Builder
- The interface would not scale correctly when moved to a different monitor. This has been resolved.
- Scheduling
- The backup delay after reboot for scheduled backups is now user configurable. This enables a custom delay to enable network shares and external disks to come on-line before starting a backup.
See here for more information.
- The message displayed in the log for a full target disk has been improved
- On some systems, tasks scheduled to run at logon would not always run. This has been resolved.
- File and Folder Backup/Restore
- There’s a new option in Restore to select the "Parent Folder" to restore when restoring to a new location.
It’s now possible to restore individual files directly into the new folder, or restore higher parent folder(s) of the selected files.
Note, if the files selected to restore are in multiple folders then the common parent folder of the selected files is used as the base parent.
See here for more information.
- Some file modified dates in File and Folder backups could be off by the DST time difference. This has been resolved.
- Use of inconsistent share name case in network share paths could lead to multiple root folders when mounting the backup in Explorer. This has been resolved.
- Customers reported a rare case where exclusion filters could be ignored in Japanese. This has been resolved.
Cloning
- We've resolved a problem where shrinking large FAT32 file systems, where the root directory cluster wasn't at a standard offset, could cause the cloned file system to be unreadable.
Note: The cluster offset indicates that the file system wasn't created by Windows, and is a rare occurrence.
viBoot
- viBoot would not respond to a theme change. This has been resolved.
- viBoot incorrectly checking password encrypted image files during VM creation. This has been resolved.
- Empty error message was displayed when attempting to change repository location. This has been resolved.
Change Block Tracker
- Change Block Tracker would sometimes fail to attach to the System volume. This has been resolved.
Image Guardian
- We have improved the attack detection algorithms to provide enhanced security.
General
- Customers were reporting issues with network share access in the UI and during backup. This has been resolved.
General UI
- The File menu option in Reflect Monitor would sometimes not be shown. This has been resolved.
- The Restore button in the Restore wizard would not disable all page items. This has been resolved.
- Customers reported that the backup log could be in mixed English and German. This has been resolved.
- Log View refresh button was not correctly finding new log files. This has been resolved.
- Log View browser view option would not correctly show the backup state image. This has been resolved.
- Existing Backups View was not showing split file total sizes alongside the single file size. This has been resolved.
- Customers reported a crash in the Existing Backups view when refreshing the list of files. This has been resolved.
- In PE Explorer the OK button was not opening selected volumes. This has been resolved.
- Scheduled backups on completion could leave the Close button disabled. This has been resolved.
- Customers reported that the backup system tray icon could not be shown. This has been resolved.
- Windows Notifications were not translated. This has been resolved.
- The verify process after backup showed a double percentage sign. This has been resolved.
- Standalone WebView2 browser for email authentication has been removed due to Google API change.
- Existing Backups View. The size column is now configurable.
|
Bug fixes and Improvements v8.0.6161 - 7th September 2021
- General
- Localization
- Rescue Media Builder
- Recent backup folders were not always being copied when creating rescue media. This has been resolved.
- We've added a network authentication prompt when saving an ISO file to a disconnected network share.
- Technician's Rescue Media
- The option to prefix the backup filename with IMAGEID was not available in PE/Portable mode. This has been resolved.
- The toolbar for Defaults was not visible in Technician's PE/Portable mode. This has been resolved.
- File and Folder Backup
- Folders to backup were not added in alphabetic order. This has been resolved.
- File & Folder backup wizard would not use the users locale date/time format for the folder date/time. This has been resolved.
- Server Plus
- The refresh of the Exchange backup cache could lead to a "Not Responding" state. This has been resolved.
- Exchange backup could lead to an error "Not Enough Storage is available to process this command". This has been resolved.
- A program exception could occur when specifying an alternate location for SQL Server database restore. This has been resolved.
- Clone
- Email Attachments were missing for Clone operation. This has been resolved.
- Clone operations could fail to start if Forensic Copy was selected. This has been resolved.
- Image
An edge case with some flash drives could cause the last physical cluster of an imaged file system to be skipped. This has been resolved.
- Changed Block Tracker
- The CBT state in Macrium Reflect menus would not always track the current CBT state correctly. This has been resolved.
- On some systems, CBT could not be enabled on the system volume. This has been resolved.
- Image Mounting
- Mounted NTFS volumes would show as tbFAT in the Windows Explorer properties dialog when the option to "Allow access to restricted folders" had been checked. This has been resolved.
- When mounting an image the image comment would be displayed over the checkbox forcing 2 clicks to enable the checkbox. This has been resolved.
- When an image is automatically dismounted as part of consolidation, the Unmount backup dialog would retain the mounted volume. This has been resolved.
- Defaults and Settings
- The network authentication defaults now has a Test option to test connectivity.
- On 32 bit systems, default network user names were not being saved. This has been resolved.
- Log View
- The toolbar on the Log View could become corrupt when hiding the filters after switching tabs. This has been resolved.
- The Log view refresh button was clearing the log filters. This has been resolved.
- Existing Backups View
- The Existing Backups View browse option would not automatically select the file that was browsed for. This has been resolved.
- We've made the 'Folders list' column in the Existing Backups View re-sizable.
- Reflect Monitor
Cancelling a backup in Reflect Monitor could leave some buttons disabled. This has been resolved.
- Various
Various minor fixes and changes to improve Macrium Reflect.
|
Bug fixes and Improvements v8.0.6036 - 14th July 2021
|
Bug fixes and Improvements v8.0.5994 - 21st June 2021
- Windows PE
When mapping a network drive in WinPE/RE the error "A specified logon session does not exist. It may already have been terminated." could be encountered. This has been resolved.
- Rescue Media Builder
We've added the WinRE Boot\Resources folder contents to the rescue media build for improved loading visualization.
- Log View
Log Files View would crash if a completion message exceeded 255 chars, this has been resolved.
- UI Theme
- Some Edit controls in viBoot would fail to respond to mouse interactions when using dark themes. This has been resolved.
- When using the light theme, some UI elements would incorrectly display a dark grey overlay. This has been resolved.
- Consolidation
- The standalone consolidation tool 'Consolidate.exe' rejected correct passwords for password protected backups. This has been resolved.
- A rare condition could cause consolidation to fail with a 'Bad file descriptor' error. This has been resolved.
- Backup File Name
- When an Incremental or Differential had no backup set to append to and created a Full, the {BACKUPTYPE} Parameter would be incorrectly replaced with the requested type rather than 'Full'. This has been resolved.
- A backup set with alternative locations, where the Full backup was created with Macrium Reflect v7.2.4732 or earlier, could cause the backup file name to exclude the default Image ID and target the wrong directory. This has been resolved.
- We've added a 'Collision Sequence' number that persists for a backup set when the Full backup has the same name as an existing backup. This ensures that backup sets with similar names and no unique prefix, can be easily identified by file name.
- VBScript Generation
The auto generated VBScript source template failed to run with a code syntax error. This has been resolved.
- Scheduled Tasks
In some circumstances, when editing non SYSTEM account scheduled tasks, Reflect would ask for a username and password even when one had already been provided. This has been resolved.
- Restore
- The locked drive dialog incorrectly showed drive 'X:' rather than the locked volume when prompting to restore using using the rescue media. This has been resolved.
- When launching a restore from an image file in Windows Explorer, the restore Wizard would be suppressed for the first run after a reboot. This has been resolved.
- The Restore/Clone automatic resize was not locking the size of MBR WinRE recovery partitions. This has been resolved.
- Existing Backups View
The Existing Backups view could become unsynchronized with the "Folders To Search". This has been resolved.
- Backup Definition Rename
- Renaming a backup definition file could lead to an abnormal Reflect termination. This has been resolved.
- Renaming a backup definition file could cause the next definition in the list to incorrectly show the name of the file just renamed. This has been resolved.
- Network Path Auto-Complete
A long delay could be encountered when entering a UNC or network share path as a backup path. This has been resolved.
- Server Plus
- When backing up Microsoft Exchange the incorrect databases, intermittently, could be listed in the backup summary. This has been resolved.
- Exchange backups could fail with: "One or more files failed the copy process" if the database path uses a different case to the defaulted case. This has been resolved.
- viBoot
The network adapter settings in the create VM wizard could be incorrectly hidden. This has been resolved.
- Various
Various minor fixes and changes to improve Macrium Reflect.
|
Bug fixes and Improvements v8.0.5963 - 7th June 2021
- Cloning
- When running clone jobs in 'batch' mode the clone dialog would incorrectly be shown at the end of the job. This has been resolved.
- The taskbar icon could be hidden for scheduled clone jobs. This has been resolved.
Windows PE
If Windows PE has a low horizontal screen resolution of 800 pixels or less, then the restore/clone dialog could be 'clipped', rendering the 'Finish' button inaccessible. This has been resolved.
ReflectUI.exe
ReflectUI could generate a program error on Windows 8.1 and Server 2012 and cause multiple icons to appear in the notification area. This has been resolved.
Backup to DVD/CD
Reflect could generate a program exception when ejecting optical media at the end of a backup. This has been resolved.
File and Folder Backup
When searching password protected/encrypted File and Folder backups, the entered correct password was rejected causing the search to fail. This has been resolved.
Retention Warning
The backup completion warning, when the retention purge deletes all backups prior to running the backup, wasn't being suppressed if the retention rules were explicitly set to retain 1 Full. This has been resolved.
Various
Various minor fixes and changes to improve Macrium Reflect.
|
Bug fixes and Improvements v8.0.5946 - 1st June 2021
|
Bug fixes and Improvements v8.0.5945 - 30th May 2021
- File and Folder
We've resolved a problem with the File and Folder source tree control not displaying selection state correctly
- Various
Various minor fixes and changes to improve Macrium Reflect.
|
Bug fixes and Improvements v8.0.5942 - 29th May 2021
- Windows XP
Some 32 bit components could error during initialization when running on Windows XP. This has been resolved.
- Shutdown after Backup
We've resolved a problem that caused the power settings after a backup to not be honored.
- Exchange
Exchange backups would not correctly group by year when selecting a backup to restore from. This has been resolved.
- Scheduled Backups View
A rare program error could occur in the schedule history view when retrieving audit history records. This has been resolved.
- UI Improvements
- Some Windows installations, including, but not limited to, Japanese and Chinese traditional, could substitute the UI font with an incorrect typeface. This has been resolved.
- Image Guardian Event Viewer did not correctly display Warning icons. This has been resolved.
- Technicians License
The Technicians Portable application could display an incorrect expiry date in the application title bar. This has been resolved.
- Batch Backups
Backups run in 'batch mode', using a script by passing parameters to the Reflect command line would incorrectly show a completion dialog. This has been resolved.
- viBoot
viBoot could fail to load v8 encrypted image files. This has been resolved.
- Various
Various minor fixes and changes to improve Macrium Reflect.
|
Bug fixes and Improvements v8.0.5928 - 25th May 2021
- Reflect UI Font
We've changed the menu fonts used in v8.0 to be the same face and point size as in v7.x. A future update will add additional configuration options.
- Main Toolbar
The main application toolbar can now by hidden to save space. Take the 'View' > 'Toolbar' menu option.
- Log View
- To save screen space, we've added a Show/Hide button for the filter options in the Log View.
- Logs were not being purged on startup when the retention was set for zero days. This has been resolved.
- We've resolved a crash when loading log files that are empty.
- File and Folder
- File and Folder backups could incorrectly report access denied for some files when backing up. This has been resolved.
- The copied files list now shows Modified and Created dates in local time rather than UTC.
- Installer
The 32 bit installer could crash unexpectedly on some systems. This has been resolved.
- Password Reveal
Password reveal box now supports Windows Hello PIN authentication..
- MS Outlook 365
We've fixed a problem with Outlook personal account usage in the MS Outlook 365 Email Settings
|
v8.0.5903 - 17th May 2021
- Macrium Reflect v8.0 - First Public Release
We're excited to announce the official release of Macrium Reflect v8.0. Macrium Reflect v8.0 has been comprehensively overhauled to provide a better user experience, and we've added some great new functionality as well...
- Resilient File System (ReFS) and exFAT support
- Dark Theme
- Intra-Daily scheduled backups
- Removable media Imaging and Cloning support
- Automatic partition resizing when restoring or cloning to different sized disks
- New 'Existing Backups' view
- Improved File and Folder backup wizard
- Improved backup file name functionality
- New tbFAT driver for mounting File and Folder backups
- Redesigned and Improved 'Log' view
- OAuth 2.0 email authentication for Gmail and Outlook 365
- viBoot now includes Oracle VirtualBox support
Please visit our knowledgebase for more information: New in Macrium Reflect 8.0
|