| Bug fixes and Improvements v7.3.5289 - 16th October 2020 	 
	Changed Block TrackerOn some systems, CBT could execute the wrong notification handler in response to a malformed notification. This could result in the following bug checks: MULTIPLE_IRP_COMPLETE_REQUESTS, KERNEL_SECURITY_CHECK_FAILURE or ATTEMPTED_WRITE_TO_READONLY_MEMORY. This has now been resolved.
Macrium Task Scheduler
 
			Scheduled VBScript files could fail with error code 0xC1 instead of running. This has been resolved.The German language UI scheduled backups context menu could cause a program exception. This has been resolved. | 
	| Bug fixes and Improvements v7.3.5283 - 15th October 2020 	 
	Changed Block TrackerWhen removing a USB attached storage device, an APC_INDEX_MISMATCH BSoD could be generated if there was an outstanding kernel lock on the device. This has been resolved.
 | 
	| Initial Macrium Reflect v7.3 Public Release v7.3.5281 - 14th October 2020 We recommend all users upgrade to this release. 	
	Initial v7.3 ReleasePlease see this KB article for more information on what's included.
 
Changed Block TrackerAfter performing a restore of a non-system volume for which CBT had been enabled, CBT could become disabled on that volume and would not re-enable until the system had been restarted. This has been resolved.
Email NotificationsWe've enhanced OpenSSL integration and upgraded to 1.1.1h to address any potential security concerns.
 | 
	| Bug fixes and Improvements v7.2.5107 - 5th August 2020 	 	
	
	Reflect hanging after running a backupRelease 7.2.5098 could cause ReflectBin.exe to hang at the end of a backup. This has been resolved.
 | 
	| Bug fixes and Improvements v7.2.5098 - 5th August 2020 	 	
	
	VariousRestore/Clone
 
			
			We've added a new confirmation prompt when extending a partition beyond 2TB on an MBR disk. Extending beyond 2TB will cause the disk layout to be converted to GPT format and will cause MBR system disks to be non-bootable. In the rescue media, we've also added a warning to indicate that disks converted to GPT will not be accessible by Windows XP and Server 2003.
			When copying an MBR 'Active' partition to an existing non 'Active' partition the target partition may not get marked 'Active' after restoring. This has been resolved.
			Automatic system restore for 32 bit systemsIf initiating a system restore in Windows causes the boot menu to be automatically added then, for 32 bit systems, local NIC and mass storage drivers may not be copied. This has been resolved.
Changed Block Tracker
 
		Fixed a permission issue that prevented the Encrypted File System (EFS) from encrypting some files on volumes that were formatted while CBT was active.Improved compatibility with Windows 10 build 2004. Various minor fixes and changes to improve Macrium Reflect.
 | 
	| Bug fixes and Improvements v7.2.4971 - 16th June 2020 	 	
	Legacy MBR Systems
 
			For MBR Windows 10 systems the 'Create an image of the partition(s) required to backup and restore Windows' now includes the Windows Recovery partition.MBR systems using BitLocker for the Windows volume would require running 'Fix Windows boot problems' after a 'live' BitLocker restore. This has been resolved.UEFI System detectionThe Windows 10 2004 (May) update caused legacy MBR systems to be detected as UEFI. This has been resolved.
File and Folder BackupFile and Folder 'Folders to exclude' now permits trailing backslashes.
Macrium viBootviBoot Virtual Machine names are now limited to 100 characters. This prevents viBoot VMs from exceeding the Hyper-V name length limit.
Rescue Media Builder
 
		RMBuilder now prevents the boot menu being set for PE 3.1 on UEFI booting systems. PE 3.1 is legacy MBR only.RMBuilder would incorrectly report that not enough free space was available when using 1GB flash media. This has been resolved. | 
	| Bug fixes and Improvements v7.2.4952 - 29th May 2020 	 	
	Macrium Image GuardianSome customers have reported erroneous MIG block notifications and a Macrium Service process crash. This has been resolved
 | 
	| Bug fixes and Improvements v7.2.4942 - 22nd May 2020 	 
	
	Backup ProgressWe've added a live backup total progress bar to the Reflect task bar icon.
Backup blockedA few customers have noticed backups hanging after completion which could prevent the next backup from starting. We've improved the communication between backup instances to prevent a potential race condition.
ReDeploySome customers have noticed poor CPU performance after redeploying to new hardware. ReDeploy has been improved to only reset CPU drivers if a CPU change is detected
 | 
	| Bug fixes and Improvements v7.2.4884 - 9th May 2020 	 
	
	Email NotificationsSome customers have reported that Reflect notification emails have been rejected by their email service providers. This has been resolved.
 | 
	| Bug fixes and Improvements v7.2.4861 - 23rd April 2020 	 
	
	XP OnlyThis is an XP only release that resolves the error "missing bcrypt.dll" when starting Reflect.
 | 
	| Bug fixes and Improvements v7.2.4859 - 23rd April 2020 	 
	
	File and Folder BackupWe've excluded MS Volume Shadow Copy from participating in backups of removable drives. Previously, a File and Folder backup would report VSS errors before continuing if folders on a removable drive, such as a Flash drive, were included. VSS is not supported on removable media.
MS ExchangeSome customers have reported an application crash when running MS Exchange incremental backups. This has been resolved.
GPT Disk LayoutsWe've added an additional check to allow the GPT partition table to contain gaps when loading disk layouts in Reflect. It's possible that GPT partition tables can be non-contiguous if the disk has been formatted or updated using Linux.
Rescue Media
 
			To distinguish between multiple Ethernet Adapters with a similar name, the Windows PE Network Adapter dialog now shows the MAC address of each adapter.Changing the rescue media staging area volume would not always remove all the files on the old volume. This has been resolved.If a new edition of Reflect is installed, e.g, Workstation to Server, the Rescue Media Builder will now prompt for a rebuild of the rescue media. | 
	| Bug fixes and Improvements v7.2.4808 - 25th March 2020 	 
	
	German Language Version OnlyA program exception could occur when opening the verification dialog. This has been resolved.
Macrium Changed Block Tracker (MRCBT)CBT could erroneously hang on to volume locks on some systems causing problems with scheduling system volume chkdsk events, USB drive ejection and OneDrive Personal Vault. This has been resolved.
 | 
	| Bug fixes and Improvements v7.2.4797 - 19th March 2020 	 
	
	In response to potential file system corruption issues that could arise from applying some recent Windows Updates, we have reviewed our data integrity checks and implemented new features:See https://answers.microsoft.com/en-us/windows/forum/all/kb4535996/134c504e-bb55-4e3c-a5da-28794a4b6079
 Note: The first Incremental after installing may take much longer than normal. Changed Block TrackerWe've improved CBT to reset more robustly on System power failure, unexpected shutdown and unexpected device removal.
Repair option when verifying Image filesWe've added an 'Attempt repair' option when verifying image files. If block corruption is detected and the live file system contains the original data then the block is repaired by replacing with the original data. Block corruption is exceptionally rare but this additional feature is designed to further mitigate file system and storage problems. We've also added an additional command line switch to the standalone verification utility.
 See https://knowledgebase.macrium.com/display/KNOW72/Verifying+image+and+backup+filesand  https://knowledgebase.macrium.com/display/KNOW72/Verifying+image+and+backup+files+from+the+command+line
 Note: Repair isn't guaranteed and will only be attempted if the originating source volume exists on the system performing the verification.ConsolidationWe've also added verification and live repair attempt on verification failure for merged blocks during consolidation. If a data block fails verification when read for merging, the live file system is checked for the original block data.
Incremental DeltasIt was possible for a damaged Incremental index to go undetected when constructing a full index chain. This was a rare occurrence, but it could propagate further into the backup set. We have enhanced our detection code to prevent this from occurring in future.
Clone and restoreDisplay power saving settings are now honored during Clone and Restore operations. Previously the display would remain on regardless of the Windows settings.
ExchangeExchange delta incs could fail to build if multiple volumes were present for Exchange DB and meta data/log files. This has been resolved.
 | 
	| Bug fixes and Improvements v7.2.4744 - 18th February 2020 | 
	| Bug fixes and Improvements v7.2.4732 - 15th February 2020 	 
		
	Error: 'Error reading Image file'Some customers have received 'Error reading Image file' when creating Delta Incremental Images. This has been resolved.
		We recommend re-building your rescue media if currently built with v7.2.4711 to ensure compatibility with your backup sets.
Volume detectionReflect would fail to recognise file systems formatted on Dynamic volumes spanning disks with 4K sector sizes. This has been resolved.
Rescue Media Builder
 
			This release resolves a problem starting the rescue environment from the recovery boot created menu with v7.2.4711.
			Note: Running either this full installer or patch will automatically correct the current boot menu. If you continue to have problems then please launch RMBuilder and remove/re-add the boot menu.
			Moving the PE staging files to a different drive would result in duplication of the boot\Macrium sub folder. This has been resolved.
			Note: If a corrupt PE staging folder structure is detected by RMBuilder then it will be automatically deleted.
			 | 
	| Bug fixes and Improvements v7.2.4711 - 12th February 2020 	 
	
	Delta Index Saving EfficiencyWe've improved the efficiency of saving Incrementals with large delta indexes.
Technicians USBWe've enabled the Technicians USB stick and ISO to run the portable version of Reflect on Windows Hyper-V and Server Core OS's.
Phantom partitions on GPT DisksA corrupt GPT partition table on disk could cause Reflect to display 'phantom' disk partitions. This has been resolved.
Standalone ConsolidationUsing the Standalone Consolidation tool, consolidate.exe, to consolidate Incrementals where an existing consolidated Inc is between the 'From' and 'To' Inc, could cause Reflect to erroneously try to locate a previously consolidated file when the backup set was opened. This has been resolved.
File and FolderIf a File and Folder backup definition included multiple root paths for the same drive but the drive letter was specified in both upper and lower case (eg, 'D:\Data\1' & 'd:\Data\2') then the backed up paths could be erroneously split at 'D:' & 'd:' when mounting the backup in Windows Explorer. This has been resolved
Alternative locationsUsing 'Alternative locations' for a backup could break the 'Enforce an entered image or File and Folder backup file name' option in the global defaults. This has been resolved
Rescue Media Builder
 
			 When building PE 10 rescue media, RMBuilder will now correctly detect any installed PE 10 ADK of version 1803 or later.If RMBuilder found any file system errors while scanning a folder for drivers, the rescue media builder could close unexpectedly. This has been resolved.When building PE 10 rescue media, RMBuilder would sometimes unnecessarily perform a full rebuild of the wim. This has been resolved.Under certain circumstances, RMBuilder would not be able to swap between Windows PE and Windows RE. This has been resolved.Checking and un-checking the Override Drivers checkbox will no longer cause drivers to change status from "Driver already present" to "Copy host drivers". | 
	| Bug fixes and Improvements v7.2.4601 - 24th December 2019 	 
	Image MountingUn-mounting an image failed if Windows Explorer was showing the mounted drive letter. This has been resolved.
 | 
	| Bug fixes and Improvements v7.2.4594 - 23rd December 2019 	 
	Image MountingA small number of customers reported that they could not mount Macrium Reflect images after dismounting a previously mounted image. This has been resolved.
viBootWe've improved the ability for Reflect to detect bootable image files and enable the 'Boot Image' functionality in Reflect.
Bitlocker system restoreAutomatic system restores for BitLocker encrypted system volumes could perform a 'BitLocker Removal' restore instead of the expected 'BitLocker Live' restore. This has been resolved.
VBScript & PowerShellThe 'Run Once a Day' option when generating PowerShell and VBScript source files didn't behave as expected for scheduled tasks using the SYSTEM account. This has been resolved.
Verify File SystemThe 'Verify File System' default image option was not honored if unchecked for scheduled images running using the SYSTEM account. This has been resolved.
Rescue Media Builder
 					
			The default location for PE files has been moved back to $PROGRAMDATA$\Macrium\Reflect'.On Windows 7, when building Windows PE rescue media, RMBuilder will now use the Dism.exe corresponding to the wim, rather than the Dism.exe from the WAIK.On Windows XP, the radio button labels for boot menu options would sometimes be truncated. This has been resolved.If the "override WinPE compatible drivers" checkbox was unchecked, custom USB drivers would sometimes not be included into the rescue media. This has been resolved.If there was more than one version of the Windows ADK installed, RMBuilder would not copy required files from either installed ADK, and would instead prompt for a download. This has been resolved	 | 
	| Bug fixes and Improvements v7.2.4557 - 29th November 2019 	 
	Macrium Image GuardianWhile attempting to retrieve the status of a process that was closing, the MIG driver could inadvertently access an invalid address resulting in a BSoD. This has been resolved.
Rescue Media Builder
 		
			On Windows XP, the rescue media builder would sometimes give a "WIM file not found" pop-up when there was a valid WIM file present. This has been resolved.When performing an automatic restore on a system with multiple network adapters, the network adapter configuration process will be logged in more detail. | 
	| Bug fixes and Improvements v7.2.4539 - 18th November 2019 	 
	Server Plus EditionExchange backups could crash after completion if the log file couldn't be written to. This has been resolved
Incorrect ReflectUI.exe Message Box On system startup an incorrect pop-up dialog box could be shown by ReflectUI.exe. This has been resolved
viBootImages created by 'foreign' systems (not the same PC) could fail to enable the 'Boot Image' functionality in Reflect. This has been resolved
Macrium Image GuardianWe've improved the security of MIG by enhancing the malicious injection of threads into running processes.
Change Block TrackerMinor performance and stability enhancements.
Rescue Media Builder
 		
			On some systems with dynamic disks, it was possible for the location of the PE files to be incorrectly set, causing boot menu entries to fail. This has been resolved.On USB-based rescue media, un-checking the "Check for devices missing drivers on boot" checkbox and rebuilding would sometimes not make the rescue media stop prompting for missing drivers. This has been resolved.When building Technicians media, failing to create autorun.inf will no longer cause the rescue media creation to abort.If the Windows ADK version 1607 was installed but a 64-bit PE 10 zip file was used to build rescue media, any subsequent 32-bit PE 10 builds would not prompt for an updated wim but would always use the 1607 wim from the ADK. This has been resolved.RMBuilder could fail to detect a new version of Windows RE after a Windows update. This has been resolved. | 
	| Bug fixes v7.2.4524 - Free Edition Only - 31st October 2019 	 
	v7.2.4523 ErrorInternet access through a proxy server could cause v7.2.4523 Free Edition to receive a program error when checking for updates. This has been resolved.
 | 
	| Bug fixes and Improvements v7.2.4523 - 31st October 2019 	 
	XP Boot MenuWindows XP can now handle boot menu creation when the 'C:' drive has the compressed attribute set.
Auto System restoreA "Backup is running" message box could be incorrectly shown on Windows Vista when performing an automatic restore. This has been resolved.
SQL Continuous backupThe Start end End time calculations didn't take into account the local time zone. This has been resolved.
Rescue Media Builder
 
			On multi-boot systems, Windows RE WIM files for a different architecture to the current OS will now be ignored when scanning.When building rescue media with a custom wim for a different architecture to the running OS (eg. a 32-bit custom wim on a 64-bit system), RMBuilder will now detect the architecture mismatch and will not try to copy drivers from the host OS.On Windows Vista, RMBuilder would sometimes give "WIM file not found" error messages when a valid Wim file was present. This has been resolved.Since Windows PE does not support wifi, Windows PE rescue media will no longer give Unsupported Devices messages for wifi devices.In certain cases, 64-bit drivers could be automatically copied into the 32-bit drivers folder. This has been resolved.USB root hubs will now be shown in the list of devices on RMBuilder's Devices And Drivers options tab.If the Windows ADK is installed but a newer version of Windows PE is available from a zip file, RMBuilder will now build rescue media from the zip file wim rather than the ADK wim..When performing an automatic restore on a system with multiple network adapters, the rescue media would sometimes not correctly set the network configuration for all adapters. This has been resolved.USB Devices in RMBuilder now show the volume label as well as the drive letter.The 'Backup Selection' dialog in Reflect and the 'Update Drivers' dialog in RMBuilder have been updated to allow for easier browsing for network folders. | 
	| Bug fixes and Improvements v7.2.4473 - 23rd September 2019 	 
	EmailServer CoreReflect was unable to launch on Windows Server Core due to missing 'oledlg.dll' module. This has been resolved.
Microsoft Exchange Mailbox RestoreWhen exporting emails to EML file, the resulting EML file will now also include any email attachments.
Macrium Image GuardianEmptying the Recycle Bin when it contains Macrium Reflect image files will no longer result in a "blocked file operation".
Change Block Tracker
 
			CBT will now be suspended if a reboot is pending following an upgrade install.On some systems, MRCBT could receive an malformed device remove notification for USB devices that would lead to a BSoD. This has been resolved.When tracking an encrypted VeraCrypt volume, CBT would receive a lock notification for the wrong device which would eventually lead to a BSoD. This has been resolved.Rescue Media
 
			We've added a task bar button to take screenshots in PE.
			When making a backup through the rescue media, selecting "Shut down on completion" would sometimes reboot instead of shutting down. This has been resolved.	
			
			By default, on systems without WiFi adapters, the "Add WiFi Support" advanced option checkbox will now be unchecked. Systems which have previously built rescue media will be unaffected.
			
			On systems with multiple network adapters, the rescue media would not always correctly load DHCP settings or other network settings for all adapters. This has been resolved.
			
			Manually added wifi drivers were not copied into non-WinRE rescue media builds. This has been resolved.
			Clone and Restore
 
			The target list view for both clone and restore could fail to scroll to the last physical disk. This has been resolved.The "Restore Master Boot Record" settings in the Advanced dialog could fail to be applied. This has been resolved.Using Macrium Reflect English language on German systems could cause backups not to be shown in the restore view. This has been resolved. 
 
			The notification email send date could be omitted from the SMTP header. This has been resolvedNotification email addresses with labels are now allowed. E.g, (FirstName LastName <fname.lname@example.com>).Notification emails with long subject lines are now permitted. | 
	| Bug Fixes  v7.2.4440 - 27th August 2019 
	Program Error(BSoD)A system Blue Screen of Death (BSoD) could occur when imaging systems that contain ReFS formatted volumes. This has been resolved
 
 | 
	| What's New  v7.2.4433 - 20th August 2019 	 
	Microsoft Exchange 2019Support has been added for Microsoft Exchange 2019 for backup, restore and granular restore.
Update to TLS 1.2The email option in Macrium Reflect has been updated to include TLS 1.2 support.
Rescue Media FilesThe driver folders for WinPE/WinRE have been expanded to support multiple architectures and WIM versions.
 Bug Fixes 	
	Changed Block TrackerThe CBT communications protocol has been improved. The first Incremental after installing may take longer than normal.
Microsoft Exchange Mailbox RestoreDuring the same restore session if the same file was selected twice a mount error would be reported. This has been resolved.
Microsoft Exchange Backup to GUID pathThe message "Not enough memory resources are available to process this command"  could be displayed when backing up exchange to a volume guid path rather than a drive letter. This has been resolved.
USB host driver copyUSB devices could fail to be recognized if Windows PE/RE if the Rescue Media Builder had copied USB host drivers. This is now an optional setting in the RMBuilder 'Advanced' dialog and the defaulted operation for a fresh install is set to disabled. Please enable this option if necessary if you are having USB problems in the rescue media.
Rescue Media BitLocker unlock The MS utility 'manage-bde.exe' could fail to run correctly in the rescue media. This has been resolved. If this issue affects you then please re-create your rescue media after updating.
VSS Log Deletion ErrorVSS logs could be purged by date incorrectly. This has been resolved.
Technicians USBThe technicians license could be incorrectly copied to USB and ISO technicians media. This has been resolved. If this issue affects you then please re-create your rescue media after updating.
 
 Microsoft SQL RestoreServer Plus could crash when attempting to restore the SQL tail log. This has been resolved.
viBoot BackupWhen creating a backup from within viBoot a password was prompted for even if the base image was not password protected. This has been resolved.
 | 
	| What's New  v7.2.4325 - 10th June 2019 	 
	Uninstall tidy upMacrium Technicians LicenseWe've improved the Technicians license product by adding the option to create a Technicians ISO image file and optical media. This offers the full functionality of the Technicians USB stick but also allows you to use it with Hyper-V VMs by attaching the ISO file to a DVD virtual device.
Clone and Restore ConfirmationWe've added an additional confirmation check box when overwriting a Clone or Restore target disk. This offers Reflect users unfamiliar with the result of a Restore/Clone operation the opportunity to confirm or deny the overwrite operation.
ReDeployWhen attempting to ReDeploy Windows 7 using PE/RE 10 or Windows 10 using PE/RE 3.1 we now prevent IDE/ACHI services and drivers from being copied from the rescue media. This has caused un-bootable systems for some customers previously.
Rescue media USB driversSome customers have reported non-functioning USB devices which was corrected by updating the USB drivers in PE. Rescue media creation will now copy any USB OEM drivers from the host OS even if 'compatible' support is detected in the PE/RE base OS.
Changed Block Tracker
 
	The CBT tracking file format has been optimized and improved for efficiency and robustness. This will require a reboot after installing and the first Incremental after reboot may take longer than normal.CBT and Reflect now ignore the PortableBaseLayer virtual disk used by the Sandbox feature in Windows 10 build 1903. Unused .msi files in folder c:\windows\installer are now removed when uninstalling Macrium Reflect.
	File and Folder Search
 We've added path matching to the search criteria when searching File And Folder backups in the restore tab. Previously this was restricted to file names only.
 Bug Fixes 	 
	BitLockerImage mountingIn rare cases images could refuse to mount if insufficient access privileges were assigned to the 'C:\Windows\Temp' folder. This has been resolved.
Incorrect information in the Disk Details UIDirectly after starting Reflect, incorrect information was shown in the 'Details' section of the Tasks list in the backup tab. This has been resolved.
Rescue Media Builder
 
	After uninstalling Reflect, the windows module 'Wimmount.sys' could be incorrectly registered leaving other applications unable to mount VHD files. This has been resolvedWindows RE could fail to build on Server 2016. This has been resolved BitLocker 'live' restores may have reverted to BitLocker 'removal' restores after the last update. This has been resolved. If this issue affects you then please re-create your rescue media after updating.
	Changed Block Tracker
 CBT could be disabled for a volume after a reboot forced by running 'chkdsk /f'. This has been resolved.
 | 
	| Server Plus Only - What's New  v7.2.4230 - 22nd April 2019 Bug Fixes 
	 
	Image Guardian
 
	MIG could block the creation of SQL backups. This has been resolved. | 
	| What's New  v7.2.4228 - 21st April 2019 	
	Image file loading speed improvementReduced the time taken for Reflect to read the indexes back from the previous files in the backup set. This is most noticeable when reading a large number of remote files.
 
 Bug Fixes 
	 
	 
	Image GuardianChange Block Tracker
 
  Fixed an issue where a TRIM operation on a Registry hive would cause a dead-lock if some third-party software was holding a lock on the Registry.Fixed an issue where CBT could not be enabled on some volumes if the list of file extents for the NTFS $LogFile spanned a 512 byte boundary. 
 
	viBootFixed an issue on some Windows 7 systems, where MIG was prevented from using the Microsoft cryptographic functions.MIG could block the creation of SQL backups. This has been resolved. Creating an Incremental image of an encrypted/password protected image would fail with invalid password. This has been resolved.
 
 | 
	| What's New  v7.2.4156 - 3rd April 2019 	
	Large NTFS Cluster SizesMacrium Reflect now includes support for volumes formatted with the NTFS file-system that have a cluster size larger than 64K.
 
 Bug Fixes 
	 
	 
	File and Folder Incorrect Progress BarChange Block Tracker
 
	On some system using Microsoft Storage Spaces the option to enable CBT could fail. This has now been resolved and CBT fully supports Storage Spaces.Performance Optimization. The frequency with which CBT flushes its internal state to disk has been reduced. Reflect Monitor would show a sliding progress Marquee instead of the actual backup progress. This has been resolved.
 WinRE Wi-Fi Connection
 It was not aways possible to switch Wi-Fi networks when more than one network was available. This has been resolved.
 PEExplorer
 The PEExplorer application in the rescue media now includes a file deletion confirmation prompt.
 'psvolacc.sys' error when browsing Images in Windows PE/RE
 An incorrect error could be displayed when browsing images if the 'Enable access to restricted folders' option was selected in Windows PE/RE. This has been resolved
 License Key Edition Change
 When changing the installed edition of Macrium Reflect the previous license key could be retained after running the installer. This has been resolved
 BitLocker Removal Warning
 When resizing a restored BitLocker unlocked image the BitLocker Removal warning message box would not be displayed. This has been resolved
 Various
 Various small bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes  v7.2.4063 - 18th February 2019 
	Macrium Changed Block Tracker (MRCBT)CBT could fail to attach to volumes where the "System Volume Information" folder was compressed with NTFS compression. This has been resolved
 
Macrium Virtual Image Boot (viBoot)The viBoot backup functionality has been put back - viBoot can now take backups of its VMs again.
 
Backup Toast NotificationsDuplicate toast notification when restoring have been removed.
 When running backups, the toast notifications will now always show the backup definition file name.
 
PowerShellPowerShell scripts running as scheduled tasks could hang after completion of a backup. This has been resolved.
 Note: Existing scripts do not need to change
 
Server Plus - Mailbox Restore
 
    Mailbox Restore will no longer incorrectly report failures when restoring to multiple mailboxes at once.If one message failed to restore then subsequent restores could cause a program exception. This has been resolved.In rare cases, Mailbox Restore on Exchange 2016 would fail to restore messages with certain extended properties. This has been resolved.On certain domain configurations, Mailbox Restore on Exchange 2016 would not always be able to restore to all mailboxes. This has been resolved.PST file export for Exchange 2016 is now supported.
 Server Plus - Exchange BackupExchange backups can now handle backups of Databases and System volumes with different sector sizes.
 Exchange encrypted Incremental backups could incorrectly force a Full backup. This has been resolved.
 
Backup LogsWhere consolidation/Retention rules are run *before* the start of a backup, the total time taken now includes the time taken for retention and consolidation.
 File And Folder email settings now include warnings and are positioned in the same log section as Image logs.
 
VariousVarious small bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.2.3957 - 21st December 2018 	
	Macrium Changed Block Tracker (MRCBT)Some customers have experienced a Windows system exception causing a BSoD if the CBT feature was installed with v7.2.3954. This has been resolved.
 
 | 
	| What's New  v7.2.3954 - 17th December 2018 	
	Compatibility with Windows 10 Insider Preview 1809 (18290/8) System Image files can now be mounted in the latest Windows 10 Insider Preview release. We've worked around the Windows Container Isolation File System (wcifs) bug that caused a GSoD with earlier releases of Reflect.
 
 Bug Fixes 
	Macrium Changed Block Tracker (MRCBT)The following issues have been resolved...
 The number of error events that CBT writes to the System event log has been significantly reduced.
 On some systems, CBT could cause a BSoD if a third-party device driver split a request to read or write from a volume into multiple, smaller reads or writes.
 On some x86 systems, CBT could fail to read the NTFS transaction log due to a low memory condition. This resulted in a failed backup reporting a read error occurred due to insufficient system resources.
 Various dates reported by CBT were displayed in Coordinated Universal Time (UTC) format, not the currently configured local time zone format.
 
Backup End Toast NotificationThe notification displayed when a scheduled backup completes now includes the xml backup definition file name.
 
Rescue Media Builder ISO FileIf an alternative Windows 'temp' path was set with insufficient space for the ISO file then RMBuilder would not report an error and create an invalid file. This has been resolved
 
VariousMinor UI changes.
 | 
	| Bug Fixes  v7.2.3906 - 29th November 2018 	
	ISO File Creation FailureRMBuilder could fail to create ISO image files. This has been resolved.
 
Macrium Image Guardian (MIG)MIG could incorrectly display a blocking notification during consolidation when the consolidation target folder was a protected network share. This has been resolved.
 
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| What's New  v7.2.3897 - 26th November 2018Note: This patch will require a Windows reboot. 
 	
	SMB 1.0 SupportWe've added a check-box to re-enable legacy SMB 1.0 support in Windows RE and PE 10 version 1709 or greater..
 
 Bug Fixes 	
	Backup Completion EmailBackup completion emails could fail to send if the senders email was specified using the 'friendly name <user@domain.com>' format. This has been resolved.
 
Rescue Media BuilderThe following issues have been resolved...
 An application error could occur if Windows RE couldn't fit on CD media.
 Old ISO files were not being deleted before creating new CD/DVD rescue media.
 External USB volume format failure.
 PE 10 rescue media would incorrectly show PE 5.0 in the Reflect application title bar
 SRT drivers were not being injected into the WIM when building rescue media.
 
One Drive update failureMacrium Service would lock OneDrive.exe and prevent Windows Update from updating the OneDrive service. This has been resolved.
 
Macrium Image Guardian (MIG)The following issues have been resolved...
 MIG would fail to detect that a Robocopy operation was accessing a backup target when Reflect was configured to use the unique volume identifier to locate backup drives.
 MIG could cause some Anti-Virus software to hang when inserting USB flash drives.
 
Macrium Changed Block Tracker (MRCBT)The following issues have been resolved...
 A BSoD could occur after removal of a USB attached storage device.
 CBT would incorrectly attach to devices flagged as having removable media.
 A BSoD could occur if a user-mode application attempted to read an offline NTFS volume.
 CBT could block formatting of some NTFS volumes, causing the format command to stall at 99%.
 
 | 
	| Bug Fixes  v7.2.3858 - 12th November 2018Note: This patch will require a Windows reboot. 
 	
	Explorer CrashSome customers have experienced a Windows Explorer crash if displaying the 'Backup Method' column when exploring folders containing Image files. This has been resolved.
 
Wi-Fi Drivers copied for Windows PEWindows PE could incorrectly load Windows RE Wi-Fi drivers at start-up and stall the boot sequence. This has been resolved.
 If this issue affects you then please create fresh Windows PE rescue media after updating.
 
Rescue Media BuilderRMBuilder.exe could crash if invalid/non-writable media was inserted when burning optical rescue media. This has been resolved.
 
Rescue Media BuilderThe Windows volume manager could cause a delay when a partition was created on USB media causing the media creation to fail. This has been resolved.
 
Backup Start DialogThe delay time selected when a schedule backup starts was not being honoured. This has been resolved.
 
Backup Failure EmailsWhen upgrading pre-7.2 backup definitions, the option to include/exclude 'Cancelled' backups from failure emails was not saved. This has been resolved.
 
Windows PE 5.0Windows PE 5.0 rescue media would incorrectly show 'PE 4.0' in the application title bar. This has been resolved.
 
Windows XP System Tray IconWhen running scheduled backups on Windows XP the Reflect Monitor system tray icon could be hidden. This has been resolved.
 
MIG NotificationsMacrium Image Guardian could show an incorrect blocking notification for ReflectBin.exe. This has been resolved.
 
Server Plus SQL backupsMacrium Image Guardian could block Server Plus backups of SQL databases. This has been resolved.
 
ShadowProtect incompatibility with CBTSome customers have reported a Windows BSOD if StorageCraft ShadowProtect was installed. This has been resolved.
 
 | 
	| Bug Fixes  v7.2.3825 - 2nd November 2018 	
	Extended Windows Shutdown TimesSome customers have experienced extended Windows shutdown times and have been unable to perform a safe Removal of USB storage devices when the Macrium Changed Block Tracker (CBT) driver is installed. This has been resolved.
 Note: This patch will require a reboot. The initial reboot will still be using the previous CBT driver, so may take an extended amount of time to shutdown.  The new CBT driver will be active after the initial reboot.
 
Windows XP/Vista/7 Scheduled Tasks Exit CodeScheduled backups on Windows XP/Vista/7 could complete with code 0xff. Tasks would complete successfully but error as the application was unloading. This has been resolved.
 
 | 
	| Initial Macrium Reflect v7.2 Public Release  v7.2.3811 - 30th October 2018 	
	Initial v7.2 ReleasePlease see this KB article for more information on what's included.
 
 | 
	| Bug Fixes  v7.1.3317 - 4th July 2018 	
	Unable to restore to an uninitialized diskRestoring to an uninitialized disk could cause the target disk not to be found and the restore to fail. This has been resolved.
 If this issue affects you then please create fresh Windows PE rescue media after updating.
 
 | 
	| Bug Fixes  v7.1.3307 - 2nd July 2018 
	
	SQL Backup failure if TLS 1.0 is disabledSQL DB authentication would fail if TLS 1.0 was disabled and TLS 1.2 enabled. This has been resolved.
 
Clone and restore error message improvementsWhen a clone or restore failed the error messages could display incorrect or cryptic error text. Typically you may have seen 'Access Denied' for a failure, however the true cause of the problem would likely have been different. The error text now displays the initial and correct reason for the failure.
 
Clone target disk could not be foundA clone could fail with an unidentified target disk. This has been resolved.
 
MIG installationMacrium Image Guardian could turn off after a reboot if installed for a single user as opposed to the default 'All Users'. This has been resolved.
 
 | 
	| Bug Fixes  v7.1.3196 - 3rd May 2018 	
	Incremental & Differential Image CorruptionIncremental and Differential images created since 17th April using Macrium Reflect v7.1.3147, 3159 or 3169 could be corrupt if the Changed Block Tracker (CBT) driver was involved in the Image creation.
 This has been resolved.
 
 Important: Please see here for more information on this bug.
 
 | 
	| Bug Fixes  v7.1.3169 - 24th April 2018 	
	Macrium Image GuardianOn some computers, a situation could arise where Macrium Image Guardian would raise its protection level to the maximum, indiscriminately blocking all modifications to any image file. This has been resolved.
 
 | 
	| Bug Fixes  v7.1.3159 - 18th April 2018 	
	Macrium Image GuardianDriver file 'mrigflt.sys' was incorrectly signed in the previous update. This has been resolved.
 
 | 
	What's New  v7.1.3147 - 17th April 2018 	
	Macrium Image Guardian The Macrium Image Guardian system components have been updated to provide enhanced performance and reliability.
 
Backup definition encryption state change mid backup setMacrium Reflect will now start a new backup set if the encryption settings in a Backup Definition is changed.
 
 Bug Fixes 
	Technicians Portable USB Add DriversThe Add Drivers Wizard in the technicians portable USB stick could fail to detect the correct version of Windows PE when reporting supported devices. This has been resolved
 
File and Folder Restore toast notificationsWhen restoring File and Folder backups, incorrect toast notifications could be displayed. This has been resolved
 
SQL backup error if the Computer DNS name is greater than 15 charactersFor SQL backup, if the default SQL instance name was used and the Computer DNS name didn't match the Computer NetBios name then the backup could fail. This has been resolved
 
ReflectMonitorPressing the 'Escape' key while viewing ReflectMonitor would cause termination of the ReflectMonitor session. This would cause a delay when restarting and possible loss of log data in the monitor Window. This has been resolved
 
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes  v7.1.2963 - 17th March 2018 	
	Windows 7/10 32 Bit BSOD when bootingA Windows Update on the 13th March has caused some Windows 7 and 10 32 bit systems to fail to load Windows after updating. The error occurs when kernel mode driver 'pssnap.sys' loads at boot time. This update removes 'pssnap.sys' from boot time configuration. Note: Simply deleting the file is insufficient to resolve the problem.
 We recommend that 32 bit installations of Macrium Reflect on XP, Vista, Windows 7, and Windows 10 upgraded from Windows 7, 32 bit operating systems update to this release.
 If you have already updated Windows and experience this error then please see this KB article for a solution:
 https://knowledgebase.macrium.com/display/KNOW7/Windows+7+32+bit+BSOD+after+MS+Windows+Update
 If you have not yet updated Windows then please update to this version of Macrium Reflect to enable Windows to update without problems.
 After updating, XP, Vista and Windows 7 32 bit systems, will no longer have 'pssnap.sys' available. If MS VSS shadow copies fail, then your backups will no-longer fall back to using 'pssnap'. Please ensure that any VSS errors are resolved to successfully complete your backups.
 
 | 
	| Bug Fixes  v7.1.2917 - 27th February 2018 	
	Rescue media crash at bootThe rescue media could fail to boot and cause a run time error. This has been resolved. 
	We recommend creating fresh Windows PE rescue media after updating.
 
 | 
	| What's New  v7.1.2899 - 21st February 2018 Bug Fixes 
	
	File and Folder search date parametersWhen searching for files in File and Folder backups, if the From and To dates were the same then this would result in no results found. This has been resolved.
Backup priority settingA bug with the backup priority setting forced backups run with the lowest priority set to run at highest. This has been resolved.
 | 
	| What's New  v7.1.2885 - 1st February 2018 
	Missing files reported when mounting backupsWhen mounting backup files, if required files are missing from the backup set then the original file names are now listed in the error message box.
 Bug Fixes 
	Synthetic Full re-started backup setsIf all incremental images are deleted from a backup set with a synthetic full image, and the set is 're-started' by creating another Incremental then 
	the error 'Invalid Parameter' would occur when mounting the Incremental image file. Additionally, a restore of this Incremental may result in the Full being restored. 
	This has been resolved.
ReDeploy improvements for NVMe host controllersWhen migrating a system to an NVMe booting device, ReDeploy required the user to specify vendor drivers for this hardware, even when the target OS has native support. This has been resolved. 
	
	
	We recommend creating fresh Windows PE rescue media after updating.
 
Macrium viBootWhen running on systems configured in any language other than English, Macrium viBoot would sometimes fail to display information about virtual machines. This has been resolved.
 | 
	| Bug Fixes v7.1.2833 - 14th January 2018: 
	MIG Service install problemThe Macrium Image Guardian Service could fail to start. This has been resolved.
 
EXT 4 File System image sizeLinux EXT 4 file system images could be unnecessarily large. This has been resolved.
 
Free Edition prompt for Windows PE rebuildThe Free Edition of Macrium Reflect could prompt for a rebuild even if the rescue media was up to date. This has been resolved.
 
 | 
	| Bug Fixes v7.1.2817 - 8th January 2018: 
	No drive letters assigned for cloned/restored partitionsCloning and restoring multiple consecutive partitions could result in volumes without drive letters assigned. This has been resolved.
 
 Free edition installed on Windows XPAn installer error during the finalise phase could cause a Windows boot failure; resolvable by taking the "Last Known Good Configuration" option. This has been resolved.
 
 | 
	| Bug Fixes v7.1.2801 - 28th December 2017: 
	Symantec Encryption Desktop drives cloning and imagingCloning and imaging of locked drives encrypted with Symantec Encryption Desktop could fail. This has been resolved.
 
 Please note that we recommend using MS BitLocker encryption where possible. Other encryption products are not fully supported by Macrium Reflect.
 
 
RDC and RDR fall back to full copyRapid Delta Restore and Clone operations could unnecessarily fall back to performing a 'full copy'. This has been resolved.
 We recommend creating fresh Windows PE rescue media after updating to avoid this problem.
 
BitLocker Removal Restore outcome messageWhen editing a saved clone definition for a 'Live' BitLocker clone a BitLocker 'Removal' message box would incorrectly be shown. This has been resolved.
 | 
	| Bug Fixes v7.1.2792 - 20th December 2017: 
	Windows 7 drive letter assignments for cloned/restored partitionsWhen cloning/restoring file systems in Windows 7, drive letter assignments may not honour the chosen options in the clone/restore wizard. This has been resolved.
Windows PE Fix Boot ProblemsAn issue was reported where Fix Boot Problems failed to resolve the target operating system. This has been resolved.
 We recommend creating fresh Windows PE rescue media after updating to avoid this problem.
 
Macrium CBT ToolsMacrium CBT Tools could sometimes fail to detect that the correct version of the mrcbt.sys driver was running and prompt the user to reboot unnecessarily. This has been resolved.
 | 
	| What's New  v7.1.2768 - 12th December 2017 
	Improved BitLocker restore processing1. New warning message box displayed for images created with this release or later if the restore outcome results in a 'BitLocker removal' restore.
 2. The source BitLocker state is now included in Image file meta data. For images created with this release or later, this is now shown as an icon in the restore wizard source drive and restore tab.
 More information on BitLocker restore outcomes can be found https://knowledgebase.macrium.com/display/KNOW7/BitLocker+Restore+Outcomes
 If your system uses BitLocker encryption then we recommend creating fresh Windows PE rescue media after updating.
 
 Bug Fixes 
	MIG and RoboCopy sync from a root folderWhen using RoboCopy to synchronise or move backup files from a drive root folder the operation could be incorrectly blocked by MIG. This has been resolved.
Backup target share authenticationAuthenticated network share backup targets could fail with 'Access Denied' if a user without write permissions has prior access. This has been resolved.
Restore problem to striped or mirrored Dynamic volumesA restore or clone could corrupt the target dynamic disk configuration if the target volume was setup up as either 'striped' or 'mirrored'. This has been resolved.
 If this issue affects you then please create fresh Windows PE rescue media after updating.
 
Macrium viBoot
 
viBoot could fail to boot encrypted images. This has been resolved.viBoot could incorrectly detect MBR disks as GPT if the source disk has remnants of a GPT header leftover from a previous initialisation. This has been resolved.viBoot would sometimes fail to start when launched from within Reflect. This has been resolved.Exchange Databases On volume mount pointsExchange backup would not check the database path for volume mount points, resulting in backup failure, this has now been resolved.
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.1.2722 - 21th November 2017: 
	MIG not disabledFor some customers, Macrium Image Guardian would still be active when disabled in the settings dialog. This has been resolved.
 | 
	| Bug Fixes v7.1.2718 - 20th November 2017: 
	MIG not disabled when 'Restart service on reboot' selectedMacrium Image Guardian would still be active when 'Restart service on reboot' was selected in the settings dialog. This has been resolved.
Macrium viBoot incorrectly identifies some MBR disks as GPTMacrium viBoot could incorrectly mount an MBR style disk, stored within an image file, as a GPT disk - if the disk had previously been initialized as a GPT disk. This has now been resolved.
 | 
	| Bug Fixes v7.1.2697 - 10th November 2017: 
	Crash When accessing the MIG settings dialogGerman language customers could experience a program crash when accessing the Macrium Image Guardian settings dialog. This has been resolved.
 | 
	| Bug Fixes v7.1.2695 - 10th November 2017: | 
	| Bug Fixes v7.1.2646 - 13th October 2017: 
	CBT causing a lock on removable drivesThe CBT driver could cause a permanent lock on external drives preventing safe ejection. This has been resolved.
Image Guardian settings dialog hangWhen clicking 'OK', without changing any MIG settings, a progress bar would be displayed and the dialog would not closed. This has been resolved.
 | 
	| What's New v7.1.2638 - 10th October 2017  
	New Macrium Image Guardian disable optionA new option 'Restart on reboot' has been added to the MIG settings dialog.
Simplify script defaultsVBScript and Powershell default options have now been merged into one group of options.
 Bug Fixes 
	Backup in PE not always honouring Partition selectionsWhen imaging in Windows PE, if partitions were de-selected in the backup wizard then the selections were not always honoured in the backup. This has been resolved.
GUID destination paths not validated correctlyWhen using a GUID volume path as a backup destination the path syntax was not validated correctly. This has been resolved.
CBT Blue Screen failureIn very rare situations, the Changed Block Tracker driver could cause a Windows BSOD if another process incorrectly attempts to write past the end of volume boundary. This has been resolved.
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.1.2619 - 2nd October 2017: 
	MIG RoboCopy rulesMIG could incorrectly disallow RoboCopy with /MIR /PURGE parameters correctly set. This has been resolved.
 | 
	| Bug Fixes v7.1.2614 - 29th September 2017: 
	Rescue Media run errorWindows PE rescue media could fail to load with a missing DLL message. This has been resolved.
 | 
	| Bug Fixes v7.1.2611 - 29th September 2017: 
	Windows XP VSS problemSome systems running Windows XP could fail to read the VSS snapshot. This has been resolved.
User overridden file names not honouredThis has been resolved.
 | 
	| Bug Fixes v7.1.2607 - 29th September 2017: 
	MIG settings dialog resource issueSystems with non UK English Windows locale would incorrectly see the MIG dialog in German. This has been resolved.
 | 
	What's New v7.1.2602 - 28th September 2017  
	See here for more information on this and additional features in 7.1
 Bug Fixes 
	DPI Scaling Issue In ReflectMonitorSome aspects of the ReflectMonitor UI would not scale correctly. This has been resolved.
viBoot Install HyperV CheckInstall of viBoot was not checking for presence of Microsoft HyperV. This has been resolved.
Image Restore Causing Unnecessary pre-boot chkdskOn some motherboards, a pre-boot chkdsk of the EFI system partition could be triggered after a system restore. This has been resolved.
Slow Backup Definition view loadBackup definition load performance has been improved.
Server Plus - Exchange Backup
 
			The file entries in the cache of Exchange backups could be duplicated. This has been resolved.Exchange backup was not correctly checking for circular logging. This has been resolved.Server Plus - Mailbox Restore
 
			When exporting mailbox items, the Location dialog would occasionally be unable to select valid folders. This has been resolved.In rare cases, Mailbox Restore on Exchange 2016 would fail to restore emails sent by no-longer-valid user accounts. This has been resolved. VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.0.2199 - 15th June 2017: 
	Empty folders missing from File and Folder incremental and Differential backupsWhen creating an Incremental or Differential File and Folder backup, folders without files were not being included in the backup. This has been resolved.
ReflectMonitor notification icon not createdThe notification icon for running backups could fail to be created at logon. This has been resolved.
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.0.2187 - 28th May 2017: 
	Program crash when retention rules deletes several hundred split filesA program error could occur when several hundred split image files are deleted during retention rule deletion. This has been resolved.
Split file sizeSplit backup files could exceed the specified maximum size by a few bytes. This has been resolved.
Program crash during auto verificationSome customers with systems running Intel Xeon processors could experience a program crash during auto verification. This has been resolved.
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.0.2173 - 15th May 2017: 
	Pause when automatically verifying imagesA 5 to 10 second pause could be experienced at the end of automatic image verification. This has been resolved.
Server Plus Exchange 2016Mailbox Restore for Exchange 2016 was not following redirects when connecting to the Autodiscover service. This has been resolved.
Exchange mailbox restore from Incremental backupOn some Exchange systems the Incremental log files were not played into the database correctly leading to restore failure. This has been resolved
Error: "The system cannot find the file specified." when saving the index for split image filesSplit images could fail if the image index and meta data exceeded the specified maximum file size when written to the final file split. This has been resolved.
Stale volume name meta dataThe volume name displayed in the Reflect restore and mount user interface would not reflect changes made after the Full image. Note: this did not affect the volume name of a restored or mounted file system. This has been resolved for newly created Incremental and Differential images.
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.0.2161 - 28th April 2017: 
	Program error when displaying BitLocker encrypted drivesAn rare program exception could occur when displaying encrypted BitLockered drives. This has been resolved.
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.0.2158 - 25th April 2017: 
	Program exception during image verificationSome customers experienced a program error during image auto verification. This has been resolved.
 
Backup performance to local disksWhen backing up to local disks the transfer rate could sometimes be erratic and slow down during the image process. This has been resolved.
Reflect Monitor icon visible when no backup was runningOn some systems the tray notification icon could be unnecessarily visible when no backup was running. This has been resolved.
 
False backup running notifications at Windows logon A backup start notification from a previous backup could incorrectly be shown at logon. This has been resolved.
 
Windows XP Scheduled backupsScheduled backup could to fail to populate the 'Scheduled Backups' tab view on Windows XP. This has been resolved.
 
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.0.2134 - 12th April 2017: 
	Scheduled task hangScheduled tasks could hang if the target drive for the backup was unavailable. This has been resolved.
 
Very slow backupsSome customers have experienced reported transfer rates of low mb/s or kb/s during disk Image backups. This has been resolved.
ReflectMonitor Hot-KeyThe keyboard letter used to launch ReflectMonitor would fail to change from the default 'M' when changed in the registry. This has been resolved.
 
 | 
	| What's New v7.0.2128 - 7th April 2017 
	Improved auto verification speedAutomatic verification speed has been improved for disk images. This reduces the time taken to automatically verify at the end of a backup.
 Bug Fixes 
	Index verification errorWhen auto verifying split image incrementals with delta indexes the verification could fail with an Index Verification or Load errors. This has been resolved.
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| Bug Fixes v7.0.2124 - 5th April 2017: 
		Failure to start on Windows XPReflect would fail to start on Windows XP/Server 2003. This has been resolved.
 
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| What's New v7.0.2117 - 3rd April 2017 
	Automatic detection of disk write performanceWhen creating a disk image Macrium Reflect will now perform a simulation of the image writing process to determine the best method for the fastest image creation time.
Additional Scheduled task conditionsYou can now select additional schedule conditions for each schedule.
Run scheduled tasks as any user in the Windows Administrators groupScheduled tasks can now be set to run using any user in the Administrators group. Take 'Other Tasks' > 'Edit defaults' > 'Schedule' to set the account.
Please see this KB article for more information on this release:
			http://knowledgebase.macrium.com/display/KNOW7/Macrium+Reflect+-+Update+3+April+2017 Bug Fixes 
	Changed Block Tracker driver updateAn issue is resolved with Microsoft Volume Shadow copy Service (VSS) hanging.   This was experienced by a few customers using previous versions of Macrium Reflect v7.
VariousVarious bug fixes and changes to improve Macrium Reflect.
 | 
	| What's New v7.0.2089 - 21st March 2017 
	Server Plus SQL Server 2016Server Plus now supports SQL Server 2016 instances.
 Bug Fixes 
	Windows 7 - Reflect hang on startupSome customers have experienced a hang when Reflect starts on Windows 7. This has been resolved.
Shut-down warning dialog not displayedWhen scheduling backups with an automatic Windows shutdown at the end, the warning dialog wasn't being displayed. This has been resolved.
Network Error: Multiple connectionsThe error 'Multiple connections to a server or shared resource by the same user, using more than a user name, are not allowed' could be shown when scheduled backups write to a network share. This has been resolved.
Backup progress not displayedGeneral improvements and fixes to the ReflectMonitor utility to display the progress of scheduled backups.
HKLM Registry permissions issueSome customers have had problems saving default settings. This release will correct registry permissions and allow application defaults and settings to persist.
 Note: If the 'Changed Block Tracker' icon in the disk view has been remaining grey on your system then this release should correct the problem after the next image is created. 
	 | 
	| Bug Fixes v7.0.2079 - 16th March 2017: 
		Performance issue when backing up to local drivesChanges have been made to improve backup performance in Reflect 7. Please see the linked release article below
 
Network share authentication issuesNetwork authentication has been improved to prevent scheduled tasks from failing due to inability to write to the backup target share.
 
Changed Block Tracker Windows event messagesFixed case where CBT Event Viewer messages were not displayed correctly. Please note that the previous release did not fix this issue.
 
For a detailed explanation of the changes in this release please see this KB article:  
		http://knowledgebase.macrium.com/display/KNOW7/Macrum+Reflect+v7.0+Update+16th+Mar+2017 | 
	| Bug Fixes v7.0.2055 - 10th March 2017: 
		Task bar icon hidden when running scheduled tasksOn some Windows systems, when running using the Windows 'built-in' Administrator account, the 'Reflect Monitor' icon in the notification area of the Windows task bar could be hidden during a scheduled task. This has been resolved
 
 Please note: You can also show the status of a running backup, and the last run backup in the current Windows session, by pressing 'Ctrl'+'Alt'+'M' at any time.Network share authentication issuesNetwork share authentication has been made more robust by automatically checking for access using both 'user name' and 'server\user name'. In addition, multiple connections to the same share no-longer result in an 'ERROR_SESSION_CREDENTIAL_CONFLICT' caused by multiple simultaneous connections.
 
Changed Block Tracker Windows event messagesFixed case where CBT Event Viewer messages were not displayed correctly..
 
 Please note: Changed Block Tracker will be enabled after installing this update. If you have manually disabled CBT then please disable again after updating.viBoot driver signingFixed a driver signing issue that affected some users of viBoot on Windows 10.
 
 | 
	| Bug Fixes v7.0.2035 - 7th March 2017: 
		Hang when splitting backup filesAn application hang could occur if the max file size is set in the backup definition or when backing up to a FAT32 destination. This has been resolved
 
Scheduled backups network authenticationScheduled backups could fail to authenticate against password protected network shares. This has been resolved and network share connection attempts are now included in the backup log
 
Failure email not sent if the backup definition xml contained errorsIf a backup definition reported 'XML Invalid' due to a disk ID mismatch then a failure email was not sent. This has been resolved
 
 | 
	| Bug Fixes v7.0.2023 - 3rd March 2017: 
		Scheduled Tasks Upgrading ErrorThis release includes a startup dialog to resolve scheduled backup problems associated with converting v6 to v7 and with task saving issues in earlier versions of v7.
 
 For more information on this please see http://knowledgebase.macrium.com/display/KNOW7/Scheduled+Tasks+Upgrade+from+v6+to+v7
 
 | 
	| Bug Fixes v7.0.2001 - 28th February 2017: 
		Scheduled Tasks Run Time ErrorSome customers have experienced scheduled tasks saved with an incorrect run time after upgrading from v6 or creating/editing new tasks in v7. This releases resolves this problem.
 
Program hang at startupAfter upgrading from v6 Reflect could at startup. This releases resolves this problem.
 After installing this update, please check your scheduled tasks and correct the run time if necessary.
 
 For more information on these problems please see http://knowledgebase.macrium.com/display/KNOW7/Macrium+Reflect+v7.0.1994+Problems
 
 | 
	| 
		Macrium Reflect v7.0.1994 - 27th February 2017 - Initial Release
	 
	New backup engineImproved incremental backup times using a new Kernel mode changed block tracker driver to track live file system changes.
Virtual Image BootInstant virtualization of Macrium Images using Hyper-V virtual machines and Macrium viBoot.
Windows Task Scheduler 2Macrium Reflect now uses the Windows Task Scheduler v2 API to save scheduled tasks on Windows Vista and later operating systems.
More Information...See here for more information on Macrium Reflect v7.
 |